For Full-Text PDF, please login, if you are a member of IEICE,
or go to Pay Per View on menu list, if you are a nonmember of IEICE.
|
Thermal-Aware Placement Based on FM Partition Scheme and Force-Directed Heuristic
Jing LI Hiroshi MIYASHITA
Publication
IEICE TRANSACTIONS on Fundamentals of Electronics, Communications and Computer Sciences
Vol.E89-A
No.4
pp.989-995 Publication Date: 2006/04/01 Online ISSN: 1745-1337
DOI: 10.1093/ietfec/e89-a.4.989 Print ISSN: 0916-8508 Type of Manuscript: Special Section PAPER (Special Section on Selected Papers from the 18th Workshop on Circuits and Systems in Karuizawa) Category: Keyword: VLSI circuit physical design, thermal placement, partitioning, reliability, force-directed algorithm,
Full Text: PDF>>
Summary:
Temperature-tracking is becoming of paramount importance in modern electronic design automation tools. In this paper, we present a deterministic thermal placement algorithm for standard cell based layout which can lead to a smooth temperature distribution over the die. It is mainly based on Fiduccia-Mattheyses partition scheme and a former substrate thermal model that can convert the known temperature constraints into the corresponding power distribution constraints. Moreover, a kind of force-directed heuristic based on cells' power consumption is introduced in the above process. Experimental results demonstrate a comparatively uniform temperature distribution and show a reduction of the maximal temperature on the die.
|
|