Optimum Remote Pre-Amplifier Parameter Design Considering Cable Repair

Norio OHKAWA  

Publication
IEICE TRANSACTIONS on Communications   Vol.E85-B   No.3   pp.655-657
Publication Date: 2002/03/01
Online ISSN: 
DOI: 
Print ISSN: 0916-8516
Type of Manuscript: LETTER
Category: Fiber-Optic Transmission
Keyword: 
remote pumping,  repeaterless transmission,  cable repair,  remote pre-amplifier,  

Full Text: PDF(59.7KB)>>
Buy this Article




Summary: 
A design method is proposed that yields the optimum remote pre-amplifier (RPRA) parameters considering cable repair, the results of include increased cable loss and insertion position uncertainty. The optimum RPRA location is given by the intersection point of optical SNR (OSNR) vs. RPRA location curves in two cases; the total cable repair loss is assumed to be inserted at the transmitter end and at the receiver end. This RPRA parameter gives the maximum OSNR in the worst loss insertion case by cable repair.