Tohru KIRYU


An Internet-Based Cycle Ergometer Health Promotion System for Providing Personally Fitted Exercise
Zhihui WANG Tohru KIRYU Mamoru IWAKI Keisuke SHIBAI 
Publication:   IEICE TRANSACTIONS on Information and Systems
Publication Date: 2005/08/01
Vol. E88-D  No. 8  pp. 1985-1992
Type of Manuscript:  PAPER
Category: Biological Engineering
Keyword: 
cycle ergometerhealth promotionmulti-tiered client/server architecturepersonally fitted exercise
 Summary | Full Text:PDF

A Flexible Distributed Computing System and Its Application for Signal Processing
Zhihui WANG Tohru KIRYU Keisuke SHIBAI Shinkichi SAKAHASHI 
Publication:   IEICE TRANSACTIONS on Information and Systems
Publication Date: 2004/02/01
Vol. E87-D  No. 2  pp. 509-512
Type of Manuscript:  LETTER
Category: Medical Engineering
Keyword: 
distributed computingJavaXMLmanagement flexibility
 Summary | Full Text:PDF

Real-Time Restoration of Nonstationary Biomedical Signals under Additive Noises
Junichi HORI Yoshiaki SAITOH Tohru KIRYU 
Publication:   IEICE TRANSACTIONS on Information and Systems
Publication Date: 1999/10/25
Vol. E82-D  No. 10  pp. 1409-1416
Type of Manuscript:  PAPER
Category: Medical Electronics and Medical Information
Keyword: 
restorationband-limitationreal-timeadditive noiseredundancy
 Summary | Full Text:PDF

Implantable Temperature Measurement System Using the Parametron Phenomenon
Yoshiaki SAITOH Akira KANKE Isamu SHINOZAKI Tohru KIRYU Jun'ichi HORI 
Publication:   IEICE TRANSACTIONS on Communications
Publication Date: 1996/08/25
Vol. E79-B  No. 8  pp. 1129-1134
Type of Manuscript:  PAPER
Category: Measurement and Metrology
Keyword: 
parametron phenomenontemperature sensorquartz resonatoroscillation-center frequencyexcitation power
 Summary | Full Text:PDF

Compensation for the Distortion of Bipolar Surface EMG Signals Caused by Innervation Zone Movement
Hidekazu KANEKO Tohru KIRYU Yoshiaki SAITOH 
Publication:   IEICE TRANSACTIONS on Information and Systems
Publication Date: 1996/04/25
Vol. E79-D  No. 4  pp. 373-381
Type of Manuscript:  PAPER
Category: Bio-Cybernetics and Neurocomputing
Keyword: 
innervation zoneconduction velocitymultichannel EMGinverse filteringbrachial biceps
 Summary | Full Text:PDF

Motion Artifact Elimination Using Fuzzy Rule Based Adaptive Nonlinear Filter
Tohru KIRYU Hidekazu KANEKO Yoshiaki SAITOH 
Publication:   IEICE TRANSACTIONS on Fundamentals of Electronics, Communications and Computer Sciences
Publication Date: 1994/05/25
Vol. E77-A  No. 5  pp. 833-838
Type of Manuscript:  Special Section PAPER (Special Section on Signal Processing and System Theory)
Category: 
Keyword: 
nonlinear filterfuzzyadaptive filterartifact eliminationseparation of superimposed signals
 Summary | Full Text:PDF

Improvement of the Time-Domain Response of a Thermodilution Sensor by the Natural Observation System
Jun'ichi HORI Yoshiaki SAITOH Tohru KIRYU 
Publication:   IEICE TRANSACTIONS on Fundamentals of Electronics, Communications and Computer Sciences
Publication Date: 1994/05/25
Vol. E77-A  No. 5  pp. 784-791
Type of Manuscript:  Special Section PAPER (Special Section on Signal Processing and System Theory)
Category: 
Keyword: 
thermodilutionnatural observation systemejection fractionrise timestep-responsereal time
 Summary | Full Text:PDF

Electrocardiogram Data Compression by the Oslo Algorithm and DP Matching
Yoshiaki SAITOH Yasushi HASEGAWA Tohru KIRYU Jun'ichi HORI 
Publication:   IEICE TRANSACTIONS on Information and Systems
Publication Date: 1993/12/25
Vol. E76-D  No. 12  pp. 1411-1418
Type of Manuscript:  Special Section PAPER (Special Section on ECG Data Compression)
Category: 
Keyword: 
compressionECGB splineDP matching
 Summary | Full Text:PDF

Automatic Correction of Left-Ventricular Pressure Waveform Using the Natural Observation Method
Jun-ichi HORI Yoshiaki SAITOH Tohru KIRYU Taizo IIJIMA 
Publication:   IEICE TRANSACTIONS on Information and Systems
Publication Date: 1992/11/25
Vol. E75-D  No. 6  pp. 909-915
Type of Manuscript:  PAPER
Category: Medical Electronics and Medical Information
Keyword: 
automatic correctionnatural observation methodcatheter manometer systemleft-ventricular pressure waveformflushing device
 Summary | Full Text:PDF